The CDV-700RP probe is specifically designed to have greater sensitivity and easily replace the existing beta/gamma probe on the CDV-700 survey meter. No modification is required! The grip on the probe is adjustable to allow for the perfect fit to Victoreen or Lionel meters. Just unplug the existing probe and plug in the CDV-700RP. (For use with CDV-700 meters only).

Detector

Type - GM tube with thin mica window. Effective Diameter: 1.75 inches (45 mm). Window Thickness: 1.4-2.0 mg/cm2

Efficiencies
Gamma - 3600 CPM/mR/hr; beta - C-14 10%, S-90/Y-90 35%

Probe construction
Anodized aluminum housing. Size - Approx. length: 22.2 cm (8.75 in.) Dia.: 7.0 cm (2.75 in.). Connector - To match either Victoreen or Lionel CDV-700 meters. Handle - adjustable Black vinyl grip.

Operating Voltage
850 - 1000 volts - 900 volts optimum

Temperature Range
-25°C to 50°C (-13°F to 122°F)

Humidity Range
0 - 90% Relative Humidity

Weight
Approx. 328 grams (11.5 oz.) without cable.