The essential tool for personal radiation protectionThe RADOS RAD-60 Personal Alarm
Dosimeter is a precise and reliable instrument for ensuring the personal safety of the user. Ideally, the RAD-60 is used in everyday radiation monitoring, in
stand-alone conditions. If your needs grow for a more sophisticated system, the versatile RAD-60 can also be integrated into an Access Control System. The RAD-60
can be switched into System Mode, for the purpose of tracking Personnel Dose records and generating compliance reports.
The design includes state-of-the-art
technology with built in memory for retrieving dose, even during power-down. It eliminates outside interference from shock and RF. The RAD-60 is easily programmed
by the user, has a digital display, and operates with a single AAA alkaline battery. Could it get any easier than this? So simple to use,
with the push of a button you can: - Turn the unit on/off
- Change the digital display to read dose or dose rate
- Select from
several dose and dose rate alarms
- Turn the chirp function on/off
- Reset integrated dose
- Perform a battery test
- The large digital
display gives instant dose or dose rate readings and the audible alarm is loud - better than 85 DBA!
Specifications
Detector Energy
compensated Si-Diode Button Functions
Front panel push button has the following selectable functions
change display priority (dose/dose rate)
switch ON/OFF
chirp ON/OFF
reset integrated dose
change alarm thresholds
activate battery testMeasurement Range Dose: 1 uSv - 9.99 Sv or 0.1 mrem - 999 rem Energy Response
Hp(10), 60 keV - 3 MeV, better than
+ or - 25%, up to 6 MeV, better than + or - 35% Dose Rate 5 uSv/h - 3 Sv/h or 0.5 mrem/h - 300 rem/h Dose Rate Linearity
Better than + or - 15% up to 3 Sv/h (300 rem/h) Calibration Better than + or -5% (Cs-137, 662 keV at 2 mSv/h), Hp(10) Audible Alarms Seven separate alarms, sound level typically better than 85 dBA at 30 cm
- integrated dose
- dose rate
- dose overflow
- dose rate overflow at 3 Sv/h or 300 rem/h
- low battery 1 and 2
- defect
Alarm Thresholds Six preset values each for integrated dose
and dose rate-push button selection Connectors Infrared communication via bottom of the dosimeter Button Functions Power Requirements
One triple A alkaline cell, typical life is 1800 hours in background (dose mode) Temperature Range -20 - + 50° C operational, humidity up to 90% RH, non-condensed -20 - + 70° C storing Weight 80 g
(including battery) Size 78 x 67 x 22 mm
Options
ADR-1 Configuration Kit , RAD-60 Carrying Cases and The
ACS Express Software - ACS Express is a state-of-the-art
Windows-based Access Control System providing logging and personnel control for restricted area entries and exits. Designed exclusively for use by Emergency
Responders. Load the software on a laptop, hook up an ADR-1 Reader and your ready to implement the system in minutes. Provides dose records and ingress/egress
controls to track personnel in radiation areas.
Manual RAD-60_Manual.pdf
|