| Manufacturers | Radiation Oncology | Medical Physics | Diagnostic Imaging | Radiation Safety | Exercise Systems |
| Atomlab 930 Thyroid Uptake System: |
|
Home : Biodex : Products : Nuclear Medicine |
Complete, mobile, self-contained system:
The Atomlab 930 is a versatile and cost-effective spectrum analysis system for performing uptake studies, bioassays, Schilling tests, wipe tests, and other user-defined tasks in the nuclear medicine environment. Engineered for portability, durability, and efficiency, the 930 handles an array of clinical tests, safety compliance tasks, and system administration/QA procedures. A powerful microprocessor guides the user through procedures, automatically performs necessary calculations, and outputs clear, concise reports. The system’s internal memory stores results on up to twenty-five patients (up to four studies per patient). The self-contained 930 system is configured on a mobile platform with locking casters and a base that measures only 30" by 31.5" (76 x 80 cm). A
two-tiered shelf supports the microprocessor/keyboard and printer. The base of the stand has a special shelf to hold an optional well counter. A 2" x 2" NaI(Tl)
detector with collimator articulates on a counterbalanced arm. Twenty-two inches (56 cm) of vertical travel allows the probe to be positioned up to 55" (140 cm)
from the floor to accommodate seated or supine patients. The probe swings more than 180° on the horizontal plane, and extends outward up to approximately 34" (86
cm) from the support column. This design makes positioning for uptake studies simple and comfortable for both patient and technologist, and allows the unit to be
easily moved for a variety of applications or storage. The system’s multi-channel analyzer has 256 channels, with separate inputs connections for the probe and
optional well counter. The system’s embedded software has specialized programs for thyroid uptake, bioassay, wipe test, Schilling test, manual (user-defined) rate
counts, system administration and quality assurance, and start-up self test. Programs print out concise, easily interpreted reports. |
![]()
The Tabletop System is self-contained,
The Atomlab 930 guides you |
Specifications MEDICAL SPECTROMETER HARDWARE: Multi-Channel Analyzer MEDICAL SPECTOMETER PROGRAMS Thyroid Uptake, Wipe Test, Bioassay, Schilling Test, Administration/QA, Manual MCA Probe: 2" x 2" Nal (T1) integral line scintillation detector with tube base Uptake Stand: 187-246 Well Counter: Optional: 187-256 Well Counter:Lead Shielding: 2" thick (5 cm) Cover: .125" thick (.32 cm) Certification: |
|
| Comprehensive Atomlab Testing and Utility Programs:: |
Thyroid Uptake Program
|
Wipe Test Program
|
Schilling Test Program with Reports for use with kits by Mallinckrodt, Bracco, Nycomed Amersham (Dicopac)
|
Bioassay Program with Report for employees and/or patients
|
Manual MCA Program with Report for performing sample counts and analysis beyond the scope of the
standardized programs
|
System Administration / Quality Assurance Program:
|
| Product Codes: |
| 187-010 | Thyroid Uptake System, Atomlab 930, 115 VAC, Mobile Mobile System includes:
|
| 187-020 | Thyroid Uptake System, Atomlab 930, 115 VAC, Tabletop Tabletop System includes:
|
| 187-025 | Thyroid Uptake System, Atomlab 930, 230 VAC, Mobile |
| 187-015 | Thyroid Uptake System, Atomlab 930, 230 VAC, Tabletop |
| Optional: | |
| 187-246 | Well Counter, 1" lead (2.5 cm) |
| 187-256 | Well Counter, 2" lead (5 cm) |
| Related: | |
| 063-139 | Rod Source, Cs-137, Calibrated, 0.1 µCi |
| 063-100 | Rod Source Set Includes Ba-133, Cs-137, Co-57, Na-22, Mn-54, Co-60 and Cd-109. |
| 101-103 | Check Source, Cs-137, 10 µCi Uncalibrated , 1" dia x .25" thick (2.5 x .64 cm) |
| 187-912 | Stand, Printer For 187-020 |
| 043-365 | Thyroid Uptake Neck Phantom, (Complete with Bottle Carrier, Capsule Holder and 12 Polyethylene bottles) |
| Harpell Associates Inc., |
| 1272 Speers Road, Unit 2, Oakville, Ontario, Canada, L6L 2X4 |
| Phone (905) 825-2588, Fax (905) 825-0234, Toll Free: 1-800-387-7168 |
| Email: Info@Harpell.ca |