Lode Portable Calibrator 2000 (919900):

Home  :  Lode  :  Products

The Portable Calibrator 2000 is meant for re-calibrating in the field of ergometers.

The Calibrator 2000 is a portable unit, easy to install and convenient to work with. Two different types of crank adapters and filling blocks for height adjustment are delivered with the Calibrator to make connection possible for a wide variety of ergometers. The ergometer is connected to the Calibrator with an intermediate shaft axis with two universal joints. The Calibrator is controlled from a PC over a RS232 line. The data can be stored and printed from the PC.

The Calibrator's main components are:
An electromotor, a servo-unit, a control unit and a torque sensor. Control is performed by the externeal connected PC which communicates with an on-board microcontroller performing the user actions. From the PC the RPM is specified and sent to the control-unit. The microcontroller manages the adjusted RPM and measures the torque value. Each rotation 400 torque measurements are carried out for highest dynamic performance. These measurements are averaged and can be readout by the PC. On the PC the user can specify the number of rotations over which the power measurements are averaged before displaying. For highest accuracy an offset correction is carried out before each ergometer calibration.

The measured data can be stored in a pre-defined calibration report in German or English, containing customer and ergometer data as well as the date of calibration. This gives the user also the possibility to create his own backup of the calibrations.

The Calibrator has a second serial port and an analog port to which Lode (or Lode compatible) ergometers can be connected to make automatic calibr ation possible. All other ergometers are calibrated in the manual mode.

The serial ports of the Calibrator are galvanical isolated.

An emergency button is on top to stop the Calibrator immediately for safety reasons.

Technical Specifications:

  • Power range: 0-500 Watt approved; 0-1000 Watt at 130 RPM.
  • Rotational speed: 0-130 RPM
  • Accuracy power:error <1.8 Watt for P<100 W, error <2% for P<100-500W
  • RPM resolution: 0,1 RPM
  • Accuracy RPM adjustment: 0,2 RPM
  • Torque resolution: 0,1 Nm
  • Maximum motor torque: 73 Nm
  • Maximum sensor torque: 100 Nm
  • Time resolving: 10 milliseconds
  • Rotation direction: clockwise, looking at the outgoing axis
  • Warming up: half an hour
  • Mains supply: Adjustable 230/115V +/-10%, 50/60Hz, 1000VA, fused resp 6,3AT/10AT
  • Outline dimensions: 64 x 20 x 45 cm without extra filling blocks.
  • Serial connections: 2 x RS232 bidirectional
  • Weight: 40 kg
  • Electromagnetic compatibility: EN 60601-1-2 conform CE
  • Approvals: PTB
  • Application: field calibration of ergometers
  • Language: English; printed data: English or German
  • Static accuracy check: performed with measure arm and basket using calibrated class M3 masses: 1kg and three 2kg masses (masses optional)

Attributes:

  • Measure arm + weight basket
  • Power supply cable
  • RS232 cable 9-9 pins
  • RS232 cable 9-15 pins
  • Analog cable
  • PC software
  • 2 safety pins
  • Crank adapter
  • Intermediate shaft axis
  • User manual
  • 2 filling blocks