Manufacturers Radiation Oncology Medical Physics Diagnostic Imaging Radiation Safety Exercise Systems

Discounted Nuclear Medicine Equipment


Echo Cardiac Stress Table (927900):

Home  :  Lode  :  Products

In the specialism echocardiology stresstesting is an important item; not just pharmaceutical stress of the heart but more and more a real stress test during echocardiology research. This kind of research requires a special stress table, an Echo Cardiac Stress Table.

A table convenient for both the physician and the patient. Only in this way, it is possible to make a safe and reliable diagnosis. Lode developed this table. The Echo Cardiac Stress Table allows to perform a stress test with a cardiac patient in supine position with an additional 45 degrees rotation over the longitudinal axis. This transversal slope to the left brings the heart in the optimal position for the echo research and researcher.

The physician can sit next to the patient without manoevring himself into impossible body positions.

Because of the minimum height above the floor and the adjustable hip and upperbody support the patient will feel as convenient as possible.

The Lode ergometer Angio comes standard with the Echo Cardiac Stress Table. The Angio can cope with both rpm dependent and independent load settings up to 300 Watts by means of the workload programmer.

The back support is adjustable and the Angio can be slided back and forth to suit leg legth. The adjustability of this custommade/usersdefined table for the specialism of echo stress provides the possibility to achieve "clear imaging" during test procedures.

The Echo Cardiac Stress Table can be used in horizontal position for other cardiac stress research.
 

Specifications:

  • Patient capacity: 160 KG
  • Angle adjustment back support panel: 0-30 degrees
  • Angle adjustment platform: 0-45 degrees
  • Height of platform at 0 degrees: 60 cm

Dimensions:

  • Table: Outline dimensions (LxWxH):  218 cm x 100 cm x 75 cm (incl. Angio)
  • Net. weight: 95 KG (200 Lb) (Excl. Angio)
  • Color: white/black/grey
  • Specs for Angio and WLP see those products.

Material:

  • Platforms: TRESPA
  • Frame: powder coated steel
  • Angio mounting plate: PETP

Material:

  • IEC 601-1, class 1, type B
  • Other standards: 93/42/EEC, EN 60601-1-2
  • Applications: Stress Echocardiology