MT-JVA-CALC SuprCalc ScreenshotThe MOSFET 20 patient dose verification system is a high-performance, cost-effective dosimetry system for use in:
  • standard patient dose verification;
  • in-vivo dosimetry;
  • total body irradiation dose measurements;
  • measurements in brachytherapy catheters,
  • radiosurgery; and
  • MED-TEC’s IMRT/3D QA Phantom™.

Isotropic MOSFET dosimeters have no angular dependence, and the response is within ±2% for 360º.

The MOSFET 20 system can measure up to 20 MOSFET dosimeters, operating independently. The reader features a bright vacuum fluorescent display screen which is easy to read in all lighting conditions.

The MOSFET 20 patient dose verification system combines accuracy and minute size with the convenience of instant dose readout. MOSFET dosimeters, with an active area of less than 0.04mm2, are smaller than TLDs and make pinpoint dose measurement a reality.

Unlike diode-based systems, MOSFETS are suitable for both photon and electron radiation from 1MeV to 20MeV. There is no need to purchase separate dosimeters for various photon and electron energies. In addition, MOSFET detectors are dose-rate independent. This high-performance system is expandable from a standard configuration of 1-5 detectors to a maximum of 20 detectors, by adding up to three bias modules.

The processor/readout module is auto ranging, eliminating manual system manipulation. Dose readings are available in user-selected units, including cGy, R, or mV. The system retains up to 20 operator-entered calibration factors. Battery back-up preserves calibration factors, time and date settings after power-down.

The standard TN-RD-50 system includes a self-contained processor/readout module, an external bias module with five dosimeter ports, a power adapter, five MOSFET detectors, and connecting cables.

 
Part #: Description
MT-TN-DVS Thomson & Nielson patient dose verification system1
MT-TN-502RDI Pack of five MOSFET isotropic detectors / dosimeters
MT-TN-502RDI-2 Pack of two MOSFET isotropic detectors / dosimeters
MT-TN-502RDV Pack of five MOSFET detectors / dosimeters
MT-TN-1002RDV Pack of five high-sensitivity MOSFET detectors / dosimeters
MT-TN-1002RDV-2 Pack of two high-sensitivity MOSFET detectors / dosimeters
MT-TN-RD-19 High sensitivity bias supply
MT-TN-RD-20 Additional bias supply module with five detector ports2
MT-TN-RD-21 Bias supply reader cable
MT-TN-RD-36 Star printer
 
System dose reproducibility (at 1 sigma)
DOSE BIAS SUPPLY
  Standard High
200 cGy <2% <0.8%
100 cGy <3% <1.2%
20 cGy <8% <3%

Dosimeter Specifications

  • 0.04mm2 active detection area.
  • Permits pinpoint measurement without patient shielding.
  • Lightweight and flexible.
  • Isotropic response of ±2% for 360º.
  • Temperature and humidity effects are negligible.
Reader Specifications
  • Vacuum fluorescent display.
  • Direct readout in user-selected units – cGy, mV, R.
  • Resolution of one unit up to a total accumulated dose of 20,000 mV.
  • Battery backup retains calibration factors and time/date settings after power down.
  • Stores up to 20 operator-entered calibration factors.
  • Readings automatically scaled.
  • Internal clock stores time and date with battery backup.
Sensitivity:
Under full buildup:
  • 2.7 mV/cGy on high-sensitivity bias.
  • 1 mV/cGy on standard bias.
  • Higher sensitivities available.
X-ray energies: 9 mV/R on high-sensitivity bias.
   
 