The Unfors Mult-O-Meter 407L is a perfect meter for service and QA of both conventional radiographic and fluoroscopic equipment. The dose range covers anything from low input dose rate measurements to the I.I. up to high output radiographic exposures. And the kVp range and sensitivity covers most needed measurements.

External Detector: Dose R/F Wide, Rate R/F Wide and Time Internal Detector: kVp RAD and Time

The Unfors Mult-O-Meter offers a cost effective and rapid way for measurements. The meter is designed with the aim to make the measurement procedure simple and straightforward. The Unfors Mult-O-Meter is extremely easy to use. Only two buttons are used to control the instrument: On/Off and Parameter for scrolling the measured values. No set-up time is needed. Just position the detector in the radiation field and expose. The specially designed LCD clearly indicates measured value and unit together. As an added benefit, you will spend your time making measurements instead of assembling your measurement equipment. For further functionality the Unfors Mult-O-Meter can be extended with internal software functions. The Extended Functions can be used for measurements of:
  • Normalization of dose
  • Dose reproducibility
  • mAs linearity
  • Simplified HVL
  • Time measured corresponding to the 75 % triglevel of the kVp waveform
  • kVp with a 5, 50, 150 ms delay
The Unfors Mult-O-Meter can optionally be equipped with an infrared link for transmission of measured data to a PC. The Unfors DAQ-10 software for Excel can be used for report making and filing. Several other models with different parameters and for other applications are available within the Unfors Mult-O-Meter family. Naturally the meters are CE approved and Unfors is certified for ISO 9001 and EN 46001.
Specifications:
kVp RAD Range (auto): 50 - 150 kVp
Minimum exposure: 7 mA at 70 kVp, 50 cm
Dose R/F Wide Range (auto): 100 nGy - 9999 Gy, (11 µR - 9999 R)
Energy dependence: < 5 % at 2.5 mm Al, (50 - 150 kVp)
Rate R/F Wide Range (auto): 100 nGy/s - 500 mGy/s, (0.7 mR/min - 3500 R/min)
Energy dependence: < 5 % at 2.5 mm Al, (50 - 150 kVp)
Time Range (auto): 1 ms - 9999 s measured with the trigger detector
Inaccuracy: 0.5 % or 3 digits
Case Unfors QA Case 1
Delivery 4 weeks, ARO