Manufacturers Radiation Oncology Medical Physics Diagnostic Imaging Radiation Safety Exercise Systems

Discounted Nuclear Medicine Equipment


Unfors RAD X-ray System 30:
Home  :  Unfors  :  Products  :  Radiation Safety
Unfors RAD X-ray System 30 is based on a self-contained Unfors Mult-O-Meter Model 303 which measures kVp, dose, rate and time in the 50 - 150 kV range. It's ideal for in-house QA checks on a regular basis. Should there be a need to document the measured data the System includes the DAQ-10 software for easy report making in Excel.

Unfors Mult-O-Meter 303 with internal detector for kVp RAD, Dose RAD, Rate RAD, Time, IR Link and Extended Functions

The Unfors X-ray Systems offer a cost effective and rapid way for measurements. The Systems are designed with the aim to make the measurement procedure simple and straightforward. All Unfors X-ray Systems comes in a customized case with a Quick Guide and a comprehensive CD-manual in. The Systems includes Extended Functions and an IR (infrared) link for transmission of measured data to a PC and the Unfors DAQ-10 software for Excel.

The customized case also holds optional accessories such as the HVL kit or even additional meters for CT, mAs or light measurements. Several Systems and X-ray meters for specific applications are available within the Unfors X-ray Service and QA product line. Naturally the meters are CE approved and Unfors is certified for ISO 9001 and EN 46001.

The Unfors Mult-O-Meter is extremely easy to use. Each meter is clearly marked with the application and models with two external detectors are marked with Dose and kVp respectively. Only two buttons are used to control the instrument: On/Off and Parameter for scrolling the measured values. No set-up time is needed. Just position the detector in the radiation field and expose. The specially designed LCD clearly indicates measured value and unit together. As an added benefit, you will spend your time making measurements instead of assembling your measurement equipment.

Specifications:
kVp RAD Range (auto): 50 - 150 kVp
Minimum exposure: 7 mA at 70 kVp, 50 cm
Dose RAD Range (auto): 100 µGy - 9999 Gy, (10 mR - 9999 R)
Energy dependence < 5 % at 2.5 mm Al, (50 - 150 kVp)
Rate RAD Range (auto): 0.1 mGy/s - 500 mGy/s, (700 mR/min - 3500 R/min)
Energy dependence: < 5 % at 2.5 mm Al, (50 - 150 kVp)
Time Range (auto): 1 ms - 9999 s measured with the trigger detector
Inaccuracy: 0.5 % or 3 digits
Extended functions Normalization of dose
Dose reproducibility
mAs linearity
Simplified HVL
Time corresponding to the 75 % triglevel of kVp waveform
kVp with a 5, 50, 150 ms delay
IR Link Equipped with an infrared interface for transmission of measured data to a PC. The IR receiver connected to the serial port of a PC, receives the measured data. For data collection and calculations, the Unfors Excel Add-in software is available for user customized reports.
Unfors DAQ-10 Software Operating system Windows 98/ME, Windows 2000, Windows XP
Microsoft Excel Office 97, 2000 and XP
Case Unfors QA Case 2
Delivery 7-10 days, ARO

Harpell Associates Inc.,
1272 Speers Road, Unit 2, Oakville, Ontario, Canada, L6L 2X4
Phone (905) 825-2588, Fax (905) 825-0234, Toll Free: 1-800-387-7168
Email:  Info@Harpell.ca