Unfors Fluoro X-ray System 41 has a wide range dose detector which measures low output dose rates to image intensifiers behind patient phantoms as well as radiographic exposures. The dose detector is very small and is firmly mounted on a 2 m cable to avoid the common problem of breaking connectors. System 41 also has a separate kVp detector which has an extra sensitivity for measurements different fluoro machines. The small detectors are easily positioned by means of the included Pen Detector Holder. With the Unfors DAQ-10 software you easily make reports directly in Excel.

Unfors Mult-O-Meter 517L with 2 external detectors for kVp FLUORO, Dose R/F Wide, Rate R/F Wide, Time, Dose/Frame, IR Link and Extended Functions

The Unfors X-ray Systems offer a cost effective and rapid way for measurements. The Systems are designed with the aim to make the measurement procedure simple and straightforward. All Unfors X-ray Systems comes in a customized case with a Quick Guide and a comprehensive CD-manual in. The Systems includes Extended Functions and an IR (infrared) link for transmission of measured data to a PC and the Unfors DAQ-10 software for Excel.

The customized case also holds optional accessories such as the HVL kit or even additional meters for CT, mAs or light measurements. Several Systems and X-ray meters for specific applications are available within the Unfors X-ray Service and QA product line. Naturally the meters are CE approved and Unfors is certified for ISO 9001 and EN 46001.

The Unfors Mult-O-Meter is extremely easy to use. Each meter is clearly marked with the application and models with two external detectors are marked with Dose and kVp respectively. Only two buttons are used to control the instrument: On/Off and Parameter for scrolling the measured values. No set-up time is needed. Just position the detector in the radiation field and expose. The specially designed LCD clearly indicates measured value and unit together. As an added benefit, you will spend your time making measurements instead of assembling your measurement equipment.

Specifications:
kVp FLUORO Range (auto): 45 - 155 kVp
Minimum exposure: 1.5 mA at 70 kVp, 50 cm
Dose R/F Wide Range (auto): 100 nGy - 9999 Gy, (11 µR - 9999 R)
Energy dependence: < 5 % at 2.5 mm Al, (50 - 150 kVp)
Rate R/F Wide Range (auto): 100 nGy/s - 500 mGy/s, (0.7 mR/min - 3500 R/min)
Energy dependence: < 5 % at 2.5 mm Al, (50 - 150 kVp)
Time Range (auto): 1 ms - 9999 s measured with the trigger detector
Inaccuracy: 0.5 % or 3 digits
Dose/Frame Range (auto): 200 nGy - 9999 Gy, (23 mR - 9999 R)
Minimum pulses/s: 10
Minimum pulse width: 1 ms
Extended functions Normalization of dose
Dose reproducibility
mAs linearity
Simplified HVL
Time corresponding to the 75 % triglevel of kVp waveform
kVp with a 5, 50, 150 ms delay
IR Link Equipped with an infrared interface for transmission of measured data to a PC. The IR receiver connected to the serial port of a PC, receives the measured data. For data collection and calculations, the Unfors Excel Add-in software is available for user customized reports.
Unfors DAQ-10 Software Operating system Windows 98/ME, Windows 2000, Windows XP
Microsoft Excel Office 97, 2000 and XP
Pen detector holder Extendable holder for Unfors Mult-O-Meter external detectors for easy positioning on I.I.'s, in buckys etc.
Case Unfors QA Case 2
Delivery 7-10 days, ARO