Unfors Fluoro X-ray System 41 has a wide range dose detector which measures low output dose rates to
image intensifiers behind patient phantoms as well as radiographic exposures. The dose detector is very small and is firmly mounted on a 2 m cable to avoid the common
problem of breaking connectors. System 41 also has a separate kVp detector which has an extra sensitivity for measurements different fluoro machines. The small
detectors are easily positioned by means of the included Pen Detector Holder. With the Unfors DAQ-10 software you easily make reports directly in Excel. Unfors Mult-O-Meter 517L with 2 external detectors for kVp FLUORO, Dose R/F Wide, Rate R/F Wide, Time, Dose/Frame, IR Link and Extended Functions The Unfors X-ray Systems offer a
cost effective and rapid way for measurements. The Systems are designed with the aim to make the measurement procedure simple and straightforward. All Unfors X-ray
Systems comes in a customized case with a Quick Guide and a comprehensive CD-manual in. The Systems includes Extended Functions and an IR (infrared) link for
transmission of measured data to a PC and the Unfors DAQ-10 software for Excel. |
| Specifications: |
| kVp FLUORO | Range (auto): 45 - 155 kVp Minimum exposure: 1.5 mA at 70 kVp, 50 cm |
| Dose R/F Wide | Range (auto): 100 nGy - 9999 Gy, (11 µR - 9999 R) Energy dependence: < 5 % at 2.5 mm Al, (50 - 150 kVp) |
| Rate R/F Wide | Range (auto): 100 nGy/s - 500 mGy/s, (0.7 mR/min - 3500 R/min) Energy dependence: < 5 % at 2.5 mm Al, (50 - 150 kVp) |
| Time | Range (auto): 1 ms - 9999 s measured with the trigger detector Inaccuracy: 0.5 % or 3 digits |
| Dose/Frame | Range (auto): 200 nGy - 9999 Gy, (23 mR - 9999 R) Minimum pulses/s: 10 Minimum pulse width: 1 ms |
| Extended functions | Normalization of dose Dose reproducibility mAs linearity Simplified HVL Time corresponding to the 75 % triglevel of kVp waveform kVp with a 5, 50, 150 ms delay |
| IR Link | Equipped with an infrared interface for transmission of measured data to a PC. The IR receiver connected to the serial port of a PC, receives the measured data. For data collection and calculations, the Unfors Excel Add-in software is available for user customized reports. |
| Unfors DAQ-10 Software | Operating system Windows 98/ME, Windows 2000, Windows XP Microsoft Excel Office 97, 2000 and XP |
| Pen detector holder | Extendable holder for Unfors Mult-O-Meter external detectors for easy positioning on I.I.'s, in buckys etc. |
| Case | Unfors QA Case 2 |
| Delivery | 7-10 days, ARO |